2429316 - 5040B30 expansion valve (tube orifice) - r+r
|  | Follow the safety instructions (See 5040 - Precautions) | 
 Removing
		(
		Refitting
Removing
		(
		Refitting )
	Place the vehicle on a lift.
                                          Drain the coolant (
                                           - 0010T84  coolant for air conditioning
system dehydrate and recharge
                                           ).
                                       1. Loosen the bands (1a) and remove the hose (1b) from the air filter
to the flow meter.
		)
	Place the vehicle on a lift.
                                          Drain the coolant (
                                           - 0010T84  coolant for air conditioning
system dehydrate and recharge
                                           ).
                                       1. Loosen the bands (1a) and remove the hose (1b) from the air filter
to the flow meter.

|  | Seal the disconnected connectors, using suitable plugs, to prevent humidity and impurities from entering the system. | 

|  | Do not reuse the seals when refitting. | 

 Refitting
		(
		Removing
Refitting
		(
		Removing )
	Check that the expansion valve is not damaged.Position the new gaskets on the expansion
valve, then secure it using the bolts.
		)
	Check that the expansion valve is not damaged.Position the new gaskets on the expansion
valve, then secure it using the bolts.|  | Replace the O-rings for the connectors. Only use green coloured seals, resistant to R134A coolant fluid. Lubricate the thread of the connectors using anti-freeze. | 
|  | Fastening | Component | Ø | Value(daNm) | 
|---|---|---|---|---|
| 1b | Bolt | COOLANT SYSTEM FITTINGS | M6 | 0.9 | 
|  | Fastening | Component | Ø | Value(daNm) | 
|---|---|---|---|---|
| 2b | Bolt | COOLANT SYSTEM FITTINGS | M6 | 0.9 | 