2427636 - Z50 MIXTURE STRENGTH ERROR

The diagnostic equipment signals the following error: Mixture strength
Results of the tests
0PRELIMINARY CHECKSAll OKProblems metOperation
Connect the diagnostic equipment (Examiner or Examiner Plus) and record the errors and environmental parameters.Check for the 'Mixture strength' error onlyEnd of diagnosisThe 'Upstream Lambda signal' error is presentContinue according to the instructions for the See table   Z56  UPSTREAM LAMBDA SENSOR SIGNAL ERROR
Only the 'Mixture strength', 'Misfire', 'Catalyzer' and/or 'Downstream Lambda signal' errors are presentContinue to Step 1
Other errors are presentIdentify and eliminate the cause of the problem
1ERROR DETAIL CHECKAll OKProblems metOperation
Check the detail of the 'Mixture strength' errorEnd of diagnosisThe detail is 'Rich system'Continue according to the instructions for the See table   Z51  RICH FUEL SYSTEM
The detail is 'Idle too rich'Continue according to the instructions for the See table   Z51  RICH FUEL SYSTEM
The detail is 'Lean system'Continue according to the instructions for the See table   Z52  LEAN FUEL SYSTEM
The detail is 'Idle too lean'Continue according to the instructions for the See table   Z52  LEAN FUEL SYSTEM