2427579 - L01 CLIMATE CONTROL NOT WORKING / UNDER NO CIRCUMSTANCES
When the appropriate on/off button is pressed, the climate control sytem does not work.|  | The climate control Node supply is protected by special fuses; | 
| Results of the tests | ||||
| 0 | PRELIMINARY CHECK | All OK | Problems met | Operation | 
|---|---|---|---|---|
| Check: 
 | Continue to Step 1 | Fuses blown | Change blown fuses | |
| Relay damaged | Replace relay | |||
| Gas pressure not correct | Eliminate leaks and top up climate control system Op. 5040A10 | |||
| 1 | CHECKING WITH DIAGNOSTIC EQUIPMENT | All OK | Problems met | Operation | 
| Connect the diagnostic equipment and check for errors: 
 | Continue to Step 4 | Climate control system node not working. | Continue to Step 2 | |
| CAN line error. | Continue following the instructions for the diagnostic equipment. | |||
| 2 | ELECTRICAL CIRCUIT CHECK | All OK | Problems met | Operation | 
| Check the climate control system node power supply See E6020 AIR CONDITIONING | Continue to Step 3 | No power supply | Restore broken electrical connection See E6020 AIR CONDITIONING | |
| 3 | CHECK ELECTRICAL CONNECTIONS | All OK | Problems met | Operation | 
| Check the electrical connections for the climate control system node, in particular making sure that each individual pin is correctly connected and inserted in its housing. | Continue to Step 4 | Electrical connections not working. | Restore damaged electrical connection. | |
| 4 | CHECKING WITH DIAGNOSTIC EQUIPMENT | All OK | Problems met | Operation | 
| Keep the Examiner connected and check the engine control Node for: 
 | Continue to Step 5 | Relay not working | Change compressor control relay | |
| Wiring faulty | Renew the wiring | |||
| Error at linear sensor | Continue to Step 5 | |||
| Electric fan defective | Replace the fan | |||
| Fan wiring interrupted | Renew the wiring | |||
| 5 | COMPRESSOR ENGAGEMENT CHECK | All OK | Problems met | Operation | 
| Check: 
 | Continue to Step 6 | Compressor will not come on | Check and, if necessary, renew the continuity/insulation for the electrical connection between the engine management control unit and the climate control system pressure sensor See E6021 COMPRESSOR ENGAGEMENT | |
| 6 | CHECK ON CORRECT OPERATION | All OK | Problems met | Operation | 
| Replace the climate control system pressure sensor and check that the fault is no longer present | End of diagnosis | |||