|  |  | Results of the tests | 
| 0 | PRELIMINARY CHECK | All OK | Problems met | Operation | 
|---|
|  | Check
the condition of the fan fan power supply fuses and relay. | Continue to Step 1 | Fuses blown | Change blown fuses | 
| Relay damaged | Change damaged relay | 
| 1 | CHECKING WITH DIAGNOSTIC EQUIPMENT | All OK | Problems met | Operation | 
|---|
|  | Connect
an Examiner and check fan motor operation via active diagnosis. | Continue to Step 5 | Fan motor malfunction | Continue to Step  2 | 
| 2 | ELECTRICAL CIRCUIT CHECK | All OK | Problems met | Operation | 
|---|
|  | Check
fan motor power supply  See   E6020  AIR CONDITIONING | Continue to Step 3 | No power supply | Restore continuity/insulation
of the electrical connection between fan motor and  fan control
unit  See   E6020  AIR CONDITIONING | 
| 3 | ELECTRICAL CIRCUIT CHECK | All OK | Problems met | Operation | 
|---|
|  | Check
continuity/insulation of the electrical connection between fan motor
and  climate control system node  See   E6020  AIR CONDITIONING | Continue to Step 4 | Electrical conection broken
or not insulated. | Restore electrical connection continuity/insulation.
  See   E6020  AIR CONDITIONING | 
| 4 | CHECK ON CORRECT OPERATION | All OK | Problems met | Operation | 
|---|
|  | Check
that the fault is no longer present. | End of diagnosis | Fault persists | Change  fan motor | 
| 5 | CHECK ON CORRECT OPERATION | All OK | Problems met | Operation | 
|---|
|  | Check
that the fault is no longer present | End of diagnosis | Fault persists | Change the climate control
system node |