2427549 - K40 BATTERY CHARGING WARNING LIGHT NOT WORKING

When the ignition is turned on, the generator warning light does not come on.
Results of the tests
1CHECK WITH DIAGNOSTIC EQUIPMENTAll OKProblems metOperation
Connect the Examiner to the diagnostic socketCarry out the active diagnosis of the warning lightsContinue to Step 2The warning light does not come on Replace instrument panel Op. 5560B11
2CHECKING ELECTRICAL EQUIPMENTAll OKProblems metOperation
Check body computer power supply is correct, particularly the D+ and +15 signal See   E5010  STARTING AND RECHARING Continue to Step 3Body Computer supply incorrectRestore correct power supply
3BATTERY CHECKAll OKProblems metOperation
Check the operation of the batteryContinue to Step 4Battery not workingReplace the battery Op.   5530B10 
4CHECK ON CORRECT OPERATIONAll OKProblems metOperation
Check that the fault is no longer present End of diagnosis.