2427571 - K95 WARNING LIGHT SYMBOLS DO NOT COME ON / (IN INSTRUMENT PANEL)

With the ignition ON, the timed operation of certain warning lights does not take place and, with the engine running, the instruments are not working.
Results of the tests
0PRELIMINARY CHECKSAll OKProblems metOperation

Connect the EXAMINER diagnostic equipment and check the CAN NETWORK INFORMATION:

  • For inactive control units
  • For control units with errors
  • For CAN control units with errors
Continue to Step 1Presence of fault in the CAN Continue as instructed by the tester
Impossible to converse with the Body ComputerContinue to Step 5
1CHECK WITH DIAGNOSTIC EQUIPMENTAll OKProblems metOperation
Using the Examiner check, in the Instrument Panel Node ambient, that there are no errors and the following parameters are presentContinue to Step 4There are errorsContinue in accordance with the instructions for the diagnostic equipment
Impossible to converse with the instrument panelContinue to Step 2
2ELECTRIC POWER SUPPLY CHECKAll OKProblems metOperation
Check that the Instrument Panel Node electrical power supply is correctContinue to Step 3Positive and/or earth electrical power supply faultyReplace the component involved (if a fuse is involved, search for the cause of the problem)
3CHECK ELECTRICAL CONNECTIONSAll OKProblems metOperation
Check the electrical connections between the Body Computer and the Instrument Panel, in particular that each individual pin is correctly connected Continue to Step 4Electrical connections not workingRestore damaged electrical connections.
4CHECK WITH DIAGNOSTIC EQUIPMENTAll OKProblems metOperation
Using the Examiner check, in the Body Computer Node ambient, that there are no errors Continue to Step 7Impossible to connect with the Body Computer control unitContinue to Step 5
There are errorsContinue in accordance with the instructions for the diagnostic equipment
5ELECTRIC POWER SUPPLY CHECKAll OKProblems metOperation
Check that the Body Computer Node electrical power supply is correct.Continue to Step 6Positive and/or earth electrical power supply fault. Replace the defective component (if a fuse is involved, search for the cause of the problem).
6CHECK WITH DIAGNOSTIC EQUIPMENTAll OKProblems metOperation
Using the Examiner, check the possibility of connecting with the Body Computer Node.Continue to Step 5Impossible to connect with the Body Computer control unit.Replace the Body Computer Op. 5505A32
7CHECK ON CORRECT OPERATIONAll OKProblems metOperation
Check that the fault is no longer present End of diagnosisThe fault persistsReplace the instrument panel Op. 5560B11