2427600 - P10 CENTRAL LOCKING / NOT WORKING

When the door lock is operated with the mechanical key or from inside, via the controls on the tunnel control panel, the central locking system does not work.
The door unlocking/locking request reaches the body computer node from the door nodes via the the B-CAN. The body computer node sends the command to the door nodes which unlock/lock the side doors and it directly controls the unlocking/locking of the boot.
Results of the tests
0PRELIMINARY CHECKAll OKProblems metOperation
Check the 'independent driver door' option is deactivated.Continue to Step 1Function enabledDisable the instrument panel node function
1PRELIMINARY CHECKAll OKProblems metOperation
Check the problem does not persist by unlocking/locking the door using the lock in the remaining door or the door unlocking and locking buttons in the tunnel control panel.Continue to Step 3Problem persists.Continue to Step 2
2CHECKING WITH DIAGNOSTIC EQUIPMENTAll OKProblems metOperation
Connect the Examiner and carry out active diagnosis on the defective door node.Continue to Step 3The door does not close/openContinue to Step 4
3CHECKING WITH DIAGNOSTIC EQUIPMENTAll OKProblems metOperation

Keep the Examiner connected and check:

  • for inactive control units;
  • for control units with errors;
  • for control units with error in CAN line
Continue to Step 8anomalies.Continue following the instructions for the diagnostic equipment.
4CHECKING WITH DIAGNOSTIC EQUIPMENTAll OKProblems metOperation
Using the Examiner diagnostic equipment, check the change is status of the switch in the lock when the key is used. Continue to Step 7The status signal for the lock switch has not been correctly downloaded.Continue to Step 5
5ELECTRICAL CIRCUIT CHECKAll OKProblems metOperation
Check continuity/insulation of the electrical connection between the defective door lock and the door node. See   E3040  CENTRAL LOCKING Continue to Step 6Electrical conection broken or not insulated.Restore the electrical connection See   E3040  CENTRAL LOCKING
6CHECK ON CORRECT OPERATIONAll OKProblems metOperation
Check that the fault is no longer present.End of diagnosisProblem persistsReplace the defective door lock
7CHECK ON CORRECT OPERATIONAll OKProblems metOperation
Check that the fault is no longer present.End of diagnosisProblem persistsReplace the defective door Node
8CHECK ON CORRECT OPERATIONAll OKProblems metOperation
Check that the fault is no longer present.End of diagnosisProblem persists.Replace the Body Computer