3237837 - 1080A20 smokiness at exhaust - check with opacimeter
Start the engine and warm up until the radiator cooling fan comes on for the second time.|  | Leave as little time as possible between the engine preheating stage and the moment the test begins and avoid a prolonged idling period. | 
|  | Check that sensor diameter is at least 0.22 times exhaust pipe diameter. | 
|  | Ensure that the exhaust gas uptake fitting joints are effective enough to prevent leaks. | 
|  | Check that the sensor uptake pipe from the exhaust tail-pipe to the fume measurement device is on an upward slope and does not include acute angled kinks. | 
|  | Ensure that the counter-pressure to the sensor is as specified and does not exceed 7.5 mbar during the test. | 
|  | The readings are considered to have stabilised when four consecutive readings are within a 0.25 m -1 range and are not in decreasing order. | 
|  | Measurement | Value | |
|---|---|---|---|
| - | Exhaust fumes (m¯ 1) | 1.19 |