3233141 - P11 CENTRAL LOCKING / NOT WORKING WITH REMOTE CONTROL
When the central locking is operated using the remote control the doors do not open / close at all.| Results of the tests | ||||
| 0 | PRELIMINARY CHECKS | All OK | Problems met | Operation | 
|---|---|---|---|---|
| Check the charge of the remote control battery incorporated in the keyCheck the correct operation of the central locking using the key | Continue to Step 1 | Remote control battery charge low | Replace battery | |
| The central locking does not work with the key either | See table P10 | |||
| 1 | CENTRAL LOCKING ELECTRICAL CIRCUIT CHECK | All OK | Problems met | Operation | 
| Check, in order: 
 | Continue to Step 2 | Connections not correct | Restore connections | |
| Component defective | Replace the component involved (if a fuse is involved, search for the cause of the problem) | |||
| Receiver not working | Replace the receiver Op. 5080E30 | |||
| 2 | CORRECT OPERATION CHECK | All OK | Problems met | Operation | 
| Check that the fault is no longer present | End of diagnosis | Fault persists | Search for the fault starting from another symptom' | |
| Results of the tests | ||||
| 0 | PRELIMINARY CHECKS | All OK | Problems met | Operation | 
|---|---|---|---|---|
| Check the charge of the remote control incorporated in the keyCheck that the central locking is working properly using the key | Continue to Step 1 | Remote control battery run down | Replace battery | |
| Central locking mechanical fault | See table P10 CENTRAL LOCKING | |||
| 1 | REMOTE CONTROL RECEIVER CHECK | All OK | Problems met | Operation | 
| Check the supply, earth and connections with the integrated electric windows central locking control unit | Continue to Step 2 | Connections damaged | Restore the correct connections | |
| Component defective | Replace the alarm remote control receiver | |||
| 2 | CENTRAL LOCKING ELECTRICAL CIRCUIT CHECK | All OK | Problems met | Operation | 
| Check, in order: 
 | Continue to Step 3 | Component defective | Replace the component involved (if a fuse is involved, search for the cause of the problem) | |
| Connection damaged | Restore connections | |||
| 3 | INTEGRATED ELECTRIC WINDOWS CENTRAL LOCKING ELECTRONIC CONTROL UNIT CHECK | All OK | Problems met | Operation | 
| Check that the integrated electric windows central locking control unit is working properly | Continue to Step 4 | Control unit not working | Replace integrated electric windows central locking control unit ( Op. 5505A18 ) | |
| 4 | CORRECT OPERATION CHECK | All OK | Problems met | Operation | 
| Check that the fault is no longer present | End of diagnosis | Fault persists | Search for the fault starting from another symptom' | |