|  |  | Results of the tests | 
| 0 | PRELIMINARY CHECKS | All OK | Problems met | Operation | 
|---|
|  | Place
the key in the ON position and check that the recharging warning
light comes on (it should then go out when the engine is started
up). | Continue to Step 
                              1 | The recharging warning
light does not come on | See table 
                                 K40 | 
| 1 | CHECK STARTER MOTOR CONNECTIONS | All OK | Problems met | Operation | 
|---|
|  | Check
the connections between the battery, alternator and starter motor
(
                               See   E5010  STARTING AND RECHARING 
                              ). | Continue to Step 
                              2 | Connections not correct | Restore the connections | 
| 2 | CHECK STARTER MOTOR | All OK | Problems met | Operation | 
|---|
|  | Check
condition and correct operation of starter motor. | Continue to Step 
                              3 | Starter motor faulty. | Overhaul or replace the starter
motor. | 
| 3 | CHECK CORRECT OPERATION | All OK | Problems met | Operation | 
|---|
|  | Check
that the fault is no longer present | End of diagnosis | Fault persists | Search for the
fault starting from another symptom' |