3239173 - 5040B Check on operation of air conditioning system (pressures)
The test should be carried out
at ambient temperatures of between 18 ° C and 30 ° C.
Close all the doors and windows.Position the gear lever in neutral.Start up the engine and let it reach 1250
- 1300 rpm.
Connect the vehicle system to the special recharging
equipment (see Op.
5040A10 Air conditioning
refrigerant CIRCUIT - Draining and Refilling
),
so that the low pressure values (1a) (pressure gauge A) and the
high pressure values (1b) (pressure gauge B) can be read.
Make sure that the air conditioning is switched
off (A/C button released and LED off).Switch on the recirculation (button pressed).Place the fan speed selector in position
"2".Place the temperature selector in the maximum cold
position.Place the distribution selector in the "frontal"
position.
Check on the recharging equipment high and
low pressure gauges that the pressure is 5 - 6 bar.Switch on the air conditioning (A/C button
pressed and LED on).Check, within a minute, that the reading
on the low pressure gauge is 2.5 - 3.0 bar and that on the high pressure
gauge is 15 - 16 bar.Wait for the engine cooling fan to switch
on and check, on the low pressure gauge, that the pressure is 1.5
- 1.8 bar and, on the high pressure gauge, that the pressure is
10 - 12 bar.