3237529 - 1048A34 sleeve(s) from flow meter to air supply capacity case - r + r

Removing ( Refitting ) Disconnect the battery negative terminal.

NameConnector
-Battery  A1B 
1. Disconnect the electrical connection from the intake air temperature sensor.

NameConnector
1Air temperature sensor  K42 
2. Release the band and remove the oil vapour recovery pipe from the hose.3. Loosen the bands (3a-3b) for the hose (3c) and remove it from the engine compartment.
1. Release the band and remove the oil vapour recovery pipe from the hose.2. Release the accelerator cable from the plastic retaining band at the side of the hose.3. Loosen the bands (3a-3b) for the hose (3c) and remove it from the engine compartment.
Refitting ( Removing ) Position the hose and restrict the fixing bands. Secure the accelerator cable to the plastic fixing at the side of the hose. Place the oil vapour recovery pipe in its housing on the hose in question. Connect the electrical connection to the intake air temperature sensor.Connect the battery negative terminal.