3237686 - 1056B48 timing variator solenoids - r + r

Removing ( Refitting ) Disconnect the battery negative terminal.

NameConnector
-Battery  A1B 
 - 1016A40  ignition coil cover on cylinder head- r+r 1. Disconnect the electrical connection from the phase transformer electro-magnet.

NameConnector
1Timing variator actuator  N76 
2. Undo the bolts and remove the variable valve timing electro-magnet.
Refitting ( Removing ) Fit the variable valve timing electromagnet and tighten both retaining bolts.

FasteningComponentØValue(daNm)
-BoltADVANCE VARIATOR SOLENOIDSM71.4 ± 2.0
Connect the electrical connection to the phase transformer electro-magnet.  - 1016A40  ignition coil cover on cylinder head- r+r Connect the battery negative terminal.