3239122 - 1056BB Check efficiency of hot film air flow meter

Ensure that the ignition key is in OFF position, then disconnect the battery negative terminal (   5530B10  battery - r+r ). Disconnect the electrical connection from the constant idle actuator.

NameConnector
-Idle actuator  N74 
Using the multimeter, check that the resistance between the idle actuator terminals is: 33 Ohm between pins 1 and 3; 17.5 Ohm between pins 1 and 2; 15.5 Ohm between pins 2 and 3.