3239486 - E6021 COMPRESSOR ENGAGEMENT - Functional description

Functional description

The relay J20 controls the compressor engagement circuit. The relay receives a supply from the line controlled by the ignition (INT/A) for the relay R1 protected by fuse F15 : both are housed in the junction unit B1 . The coil receives a supply controlled by the ignition (15/54) from the line from fuse F4 of the additional fuse box B98A ; the relay is energized by an earth signal coming from the engine management control unit M10 : in this way the air conditioning compressor engagement electro-magnet L20 is operated through a voltage of 12 V. Climate control unit M70 (pin 7 of connector A) sends a compressor enablement signal to four-stage pressure switch K10 . If circuit pressures are correct, the signal leaves the pressure switch to engine control unit M10 . According to its internal control logic, the control unit M10 sends the effective command to engage the compressor which energizes the relay J20 .