3237519 - 1040A74 inertia switch for electric pump supply circuit r + r

Removing ( Refitting ) Disconnect battery negative pole.

NameConnector
-Battery  A1B 
1. Unscrew fixing screws (1a) and remove plastic shield (1b) of inertia switch placed under driver's side seat.2. Unscrew fixing screws and remove inertia switch.3. Disconnect switch from electric connection.

NameConnector
3Inertia switch  I50 