3238435 - 5530B52 Battery DRIP TRAY/SUPPORT - R.R.
Removing ( Refitting ) - 5530B10 battery - r+rRelease the air duct hose from the mounting bracket on the drip tray. Remove the relay shield.1. Release the relays from the battery drip tray and remove them.2. Undo the nut fixing the air filter mounting bracket to the battery drip tray.3. Undo the two fixing nuts (3a) and move the connections/electrical wiring mounting bracket (3b) aside.4. Release the accelerator cable from the fastening on the bracket.
1. Undo the upper bolts (1a) fixing the drip tray to the bodyshell
and loosen the lower one (1b).2. Remove the battery cage.
Refitting
(
Removing
)
Place the drip tray in the battery housing.Tighten the 4 bolts fixing the battery
drip tray to the bodyshell.Secure the accelerator cable to the fastening
for the bracket on the drip tray.Position the connections/electrical wiring
mounting bracket and tighten the two fixing bolts.Tighten the nut fixing the air filter mounting
bracket to the battery drip tray.Refit the relays on the tray with the shield.Reattach the fastening for the air duct
hose to the mounting bracket for the drip tray. - 5530B10 battery - r+r