3237526 - 1048A14 air cleaner filtering element - replace.

Removing ( Refitting ) Ensure that the ignition key is in OFF position, then disconnect the negative battery terminal.

NameConnector
-Battery  A1B 
Proceed with removal  - 1048A59  PIPE from flow meter to throttle casing hose - R.R. . 1. Remove the relay protective cover.2. Release the relays from the battery drip tray and move them to the side.
1. Disconnect the electrical connection from the air flow meter.

NameConnector
1Air flow meter  K41 
1. Undo the bolts (1a) and remove the air filter cover (1b) complete with air flow meter (1c) and hose (1d).
1. Remove the air filter filter element.
Refitting ( Removing ) Place the air filter filter element back in its housing.Place the air filter cover, complete with air flow meter and hose, back in its housing and secure it using the bolts.Connect the electrical connection to the air flow meter.Fasten the relays to the battery drip tray.Place the relay protective cover back in its housing. Proceed with refitting  - 1048A59  PIPE from flow meter to throttle casing hose - R.R. . Connect the negative (-) battery terminal.