3233006 - B13 ENGINE STARTS WITH DIFFICULTY'

-
Results of the tests
0PRELIMINARY CHECKSAll OKProblems metOperation

Preliminarily check:

  • that the air filter is not blocked
  • the condition of the air intake circuit
Continue to Step 1 Air intake circuit component damagedRepair or replace the defective component
Air filter blocked Replace the filter Op.   1048A10 
1CHECKING WITH DIAGNOSTIC EQUIPMENTAll OKProblems metOperation
Connect the diagnostic equipment (Examiner or other instruments) to the diagnostic socket

Check:

  • for errors in the control unit
  • plausibility of all the parameters
Continue to Step 2 An error is detected in the control unitContinue according to the instructions for the diagnostic equipment
unreliable parametersContinue according to the instructions for the diagnostic equipment
2CHECKING WITH DIAGNOSTIC EQUIPMENTAll OKProblems metOperation
Carry out active diagnosis of canister solenoid Continue to Step 3 Solenoid valve faulty Replace the solenoid valve Op. 1080E26
3PETROL VAPOUR RECOVERY SYSTEM CHECKAll OKProblems metOperation
Check the petrol vapour recovery system seal Continue to Step 4 Air leaks Restore the correct seal
Pipes connected to supply broken Replace the pipes Op. 1080E48
4DELIVERY PRESSURE CHECKAll OKProblems metOperation
Check that the fuel pressure is correct Op.   0510C10  Continue to Step 5 Fuel pressure too low: supply pipe obstructedEliminate the blockage; if necessary replace the pipe
Low fuel pressure: defective pump Replace the pump assembly Op.   1040A70 
5CHECK ON TIMINGAll OKProblems metOperation
Check that the timing is correct Op.   0510A20  Continue to Step 6 Timing not correct Restore the correct timing Op.   1032B14 
6CHECK ON CYLINDER COMPRESSIONAll OKProblems metOperation
Carry out the cylinder compression test Op.   0510A10  Continue to Step 8 Cylinder compression insufficient Continue to Step 7
7CHECK ON CAUSE OF INSUFFICIENT COMPRESSIONAll OKProblems metOperation
Carry out R/R on head to check the valve seal Op.   1016C10  Check the condition of the cylinders/piston rings Continue to Step 8 Insufficient valve seal Overhaul the cylinder head Op.   1016C10 
Cylinders/piston rings wornRepair the leak
8CHECK ON CORRECT OPERATIONAll OKProblems metOperation
Check that the fault is no longer presentEnd of diagnosisFault persists: control unit faulty Replace engine management control unit Op.   1056B82