3237533 - 1056B09 hot film air flow meter (debimeter) r + r

Removing ( Refitting ) Disconnect the battery negative (-) terminal.

NameConnector
-Battery  A1 
1. Disconnect the electrical connection from the hot-film air flow meter.

NameConnector
1Air flow meter  K41 
Move the relays fastened to the battery cradle to one side.2. Disconnect the pipe carrying air to the throttle body from the flow meter.3. Undo bolts (3a), remove half-rings (3b) and air flow meter (3c).
Refitting ( Removing ) Fit the air flow meter and fix it using the half-rings and the nuts.Connect the hose carrying air to the throttle body to the air flow meter.Replace the relays in their seats on the battery case.Connect the electrical connection to the air flow meter.Connect the negative (-) battery terminal.