3233020 - D21 ENGINE CUTS OUT WHILST DRIVING
The engine cuts out suddenly whilst driving. Later, after starting normally, it works again| Results of the tests | ||||
| 0 | PRELIMINARY CHECKS | All OK | Problems met | Operation | 
|---|---|---|---|---|
| First
check that there is fuel in the tank and whether the inertia switch
has intervened Then check: 
 | Continue to Step 1 | Battery earth lead not correctly fixed | Restore correct fixing Op. 5530B22 | |
| Fuel filter dirty | Replace the filter element Op. 1044B20 | |||
| 1 | CHECKING WITH DIAGNOSTIC EQUIPMENT | All OK | Problems met | Operation | 
| Connect
the diagnostic equipment (Examiner or other instruments) to the
diagnostic socket check 
 | Continue to Step 2 | An error is detected in the control unit | Continue according to the instructions for the diagnostic equipment | |
| Lack of dialogue with the control unit | Restore the connection between the engine management control unit and the diagnostic connector ( See E5050 DIESEL ENGINES ELECTRONIC MANAGEMENT ) | |||
| 2 | LOW PRESSURE CHECK | All OK | Problems met | Operation | 
| Check the fuel supply circuit, low pressure side: if necessary, use the diagnostic equipment (Examiner) to measure the pressure values | Continue to Step 3 | Pressure not correct: fuel filter faulty | Replace the fuel filter Op. 1044B10 | |
| Pressure not correct: electric pump faulty | Replace the electric pump Op. 1040A70 | |||
| Pressure not correct: low pressure pipes faulty | Replace the low pressure pipes (see Assembly 1060F) | |||
| 3 | HIGH PRESSURE CHECK | All OK | Problems met | Operation | 
| Check the fuel supply circuit, high pressure side: for example, using the diagnostic equipment (Examiner) to measure the pressure values | Continue to Step 4 | Pressure not correct: pressure pump faulty | Replace the pressure pump Op. 1060E10 | |
| Pressure not correct: manifold faulty | Replace the manifold Op. 1060F30 | |||
| Pressure not correct: injectors faulty | Replace the injectors Op. 1060F10 | |||
| Pressure not correct: high pressure pipes faulty | Replace the high pressure pipes (see Assembly 1060F) | |||
| 4 | CHECK ON CORRECT OPERATION | All OK | Problems met | Operation | 
| Check that the fault is no longer present | End of diagnosis | Fault persists | Search for the fault starting from another symptom' | |