3239490 - E6021 COMPRESSOR ENGAGEMENT - Functional description

Functional description

The relay J20 controls the compressor engagement circuit. The relay receives a supply from the line controlled by the ignition (INT/A) for the relay R1 protected by fuse F15 : both are housed in the junction unit B1 . The coil receives a supply controlled by the ignition (15/54) from the line from fuse F4 of the additional fuse box B98A ; the relay is thus energized by an earth signal coming from the engine management control unit M10 : in this way the air conditioning compressor engagement electro-magnet L20 is operated through a voltage of 12 V. Climate control unit M70 ( pin 7 of connector A) sends a compressor enablement signal to four-stage pressure switch K10 . If circuit pressures are correct, the signal leaves the pressure switch and reaches engine control unit M10 . (pin 3 of connector B). According to its own internal control logic, the control unit M10 sends the command to engage the compressor (from pin 32 of connector D) which energizes the relay J20 .