3233016 - D03 ENGINE NOT RUNNING SMOOTHLY / (IRREGULAR OPERATION)

The engine does not run smoothly in all conditions (load, speed, etc.).In particular, there are brief, but intense 'flat spots'
Results of the tests
0PRELIMINARY CHECKSAll OKProblems metOperation

Check, in order:

  • the condition of the air intake circuit
  • that there are no faults in the air filter
  • whether the diesel pipes are leaking
  • that there is no water, petrol, paraffin or dirt in the fuel tank and filter
  • that the battery earth is correctly fixed
  • that there are no obstructions in the exhaust system
Continue to Step 1 Fault in air intake circuitRepair the air intake circuit
Air filter blockedReplace the filter element
Leak from diesel pipesstop the leak
Presence of water, petrol, parffin or dirt detected.Clean the tank and pipes and replace the filter element
Loose battery earth terminalRestore the correct fixing of the earth cable
Obstruction in the exhaust systemReplace the damaged system component
1CHECKING WITH DIAGNOSTIC EQUIPMENTAll OKProblems metOperation
Connect the diagnostic equipment to the diagnostic socket.

Check:

  • that there are no errors in the control unit
  • plausibility of all the parameters
Continue to Step 2 An error is detected in the control unitContinue following the instructions for the diagnostic equipment
unreliable parametersContinue following the instructions for the diagnostic equipment
2ROAD TEST WITH DIAGNOSTIC EQUIPMENTAll OKProblems metOperation
Road test the vehicle, reproducing the conditions in which the fault arises, keeping the diagnostic equipment connected.

Check:

  • that there are no errors in the control unit
  • plausibility of all the parameters
Continue to Step 3 An error is detected in the control unitContinue following the instructions for the diagnostic equipment
unreliable parametersContinue following the instructions for the diagnostic equipment
Lack of dialogue with the control unitRestore the connection between the engine management control unit and the diagnostic connector.
3CHECK ON CORRECT OPERATIONAll OKProblems metOperation
Check that the fault is no longer presentEnd of diagnosisFault persists: control unit faulty Replace control unit Op.   1060G80