3239446 - E5020 ENGINE COOLING - Functional description (Air Conditioner)

Functional description

The supply for fan N11 arrives directly from the battery from the line for the VENT maxifuse of B6 up to 2/99 or FAN 1 of B99 from 2/99: the fan therefore works when it receives an earth command. The relays J30 and J31 , specific to the cooling system, receive a supply at their coils controlled by the ignition (15/54) protected by fuse B25 up to 2/99 or fuse F4 of the additional fuse box B98A from 2/99. They are energized by an earth signal coming from the engine control unit M10 . If the engine coolant temperature reaches the first temperature stage, or the 4-stage pressure switch K10 (pin 3) signals to the control unit M10 that the first pressure stage has been reached, then the control unit M10 sends an earth signal to the 1st speed fan relay J30 which energizes the coil. The relay then sends an earth signal which, via the additional resistor O10 , operates the fan N11 which rotates at the first (slow) speed. If the engine coolant reaches a higher temperature level or the 4-stage pressure switch K10 (pin 6) signals to the control unit M10 that a higher pressure stage has been reached, then the control unit M10 sends an earth signal to the 2nd speed fan relay J31 which energizes the coil. The relay then sends an earth signal directly to the fan N11 which rotates at the maximum speed.