3239476 - E6015 ADDITIONAL HEATER - Functional description

Functional description

The additional heater control unit M75 receives a supply controlled by the ignition (INT/A) at pins 15 and U from the line protected by the fuse F6 of the additional fuse box B98B . The direct supply arrives from the battery (maxifuse J/B1 of B99 ) at pin TL through fuse F10 of junction unit B1 : this signal allows the battery voltage to be checked, i.e. the level of electrical power available. Pin 31 of M75 is earthed. Pin N of M75 receives the engine rpm signal coming from the engine management control unit M10 . Pin TW, on the other hand, is connected to the special temperature sensor K80 which measures the temperature of the coolant near the additional heater. Relays J36 and J37 control the engagement of the resistors O25 . The supply at the contact of the relays arrives from the battery from the line of the specific HEAT maxifuse, located directly on the battery A1 - connector D, while the coils - supplied by the line protected by F10 of the junction unit B1 - are energized by the control unit M75 , which operates only relay J36 to switch on plug O35 A , only relay J37 to switch on plugs O35 B and C, and both relays for all three plugs O35 . The safety relay J38 cuts off the supply to the two above-mentioned relays and consequently the heater plugs if the contact to earth is not correct. The coil of J38 is connected on one side to earth and on the other side to the metal frame of the device containing the heater plugs: this is connected to the engine earth C1 by means of a special earth loom C41 . If this connection is broken, relay J38 is energized and immediately stops the current supply to the heater plugs.