3232993 - A05 ALARM LED NOT WORKING

When the alarm is operated, the LED does not flash
Results of the tests
1CHECK WITH DIAGNOSTIC EQUIPMENTAll OKProblems metOperation
Connect the diagnostic equipment (Examiner or other instruments) to the diagnostic socket

Check, in order:

  • no faults in the alarm control unit
  • no faults in the alarm receiver
Continue to Step 2 Error detected in the control unit or receiverContinue according to the instructions for the diagnostic equipment
Dialogue failure for diagnostic equipment between the control unit and the receiver Restore the connection between the control unit and the diagnostic connector ( See   E7015  ALARM ).
2ACTIVE DIAGNOSIS WITH DIAGNOSTIC EQUIPMENTAll OKProblems metOperation
With the diagnostic equipment (Examiner or other instruments) carry out the active diagnosis of the operation of the LED. Continue to Step 3 LED not activated

Restore:

  • connections between alarm control unit and LED
  • LED earth ( See   E7015  ALARM )
LED not activated Replace the LED Op.   5580E18 
3CHECK CORRECT OPERATIONAll OKProblems metOperation
Check that the fault is no longer present.End of diagnosisFault persistsSearch for the fault starting from another symptom'