3233063 - I55 INTERIOR LIGHTS NOT WORKING / TIMED

The interior timed lights can be controlled by hand but the timing function does not work or is irregular.
Results of the tests
1CHECKING TIMED LIGHTING CIRCUITAll OKProblems metOperation

Check, in order:

  • services control unit supply
  • Connections between service control unit and door contacts
  • connections between service control unit and lights
  • service control unit earth
( See   E2510  COURTESY LIGHTS ).
Continue to Step 2 Component defectiveReplace the component involved (if a fuse is involved, search for the cause of the problem)
Connections brokenRestore connections
2SERVICES CONTROL UNIT CHECKAll OKProblems metOperation
Check that the services control unit is working properly, in particular the timed lighting function: see DESCRIPTION AND OPERATION: 5505 ELECTRICAL CIRCUIT FOR INSTRUMENTS/INDICATORS Continue to Step 3 Control unit not working Replace the services control unit Op.   5505A18 
3CORRECT OPERATION CHECKAll OKProblems metOperation
Check that the fault is no longer presentEnd of diagnosisFault persistsSearch for the fault starting from another symptom'
The interior timed lights can be controlled by hand but the timing function does not work or is irregular.
Results of the tests
1CHECKING TIMED LIGHTING CIRCUITAll OKProblems metOperation

Check, in order:

  • services control unit supply
  • connections between services control unit and contacts between the doors
  • connections between service control unit and lights
  • service control unit earth ( See   E2510  COURTESY LIGHTS )
Continue to Step 2 Component defectiveReplace the component involved (if it is a fuse, search for the cause of the problem)
Connections brokenRestore connections
2COURTESY LIGHTS SUPPLY CHECKAll OKProblems metOperation

Check, in order:

  • battery link
  • junction unit
  • right rear earth
Continue to Step 3 Damaged componentsReplace the component involved
3CENTRAL LOCKING MOTORS CORRECT OPERATION CHECKAll OKProblems metOperation
Check that the door lock geared motor is working properly Continue to Step 4 Geared motor damagedReplace the geared motor
4SERVICES CONTROL UNIT CHECKAll OKProblems metOperation
Check that the services control unit is working properly Continue to Step 5 Control unit damaged Replace the services control unit ( Op.   5505A18  )
5CORRECT OPERATION CHECKAll OKProblems metOperation
Check that the fault is no longer presentEnd of diagnosisFault persistsSearch for the fault starting from another symptom'