3233079 - K10 DOORS OPEN CHECK NOT WORKING

When the doors open (one or more), the warning on the Infocenter is not activated.
Results of the tests
0PRELIMINARY CHECKSAll OKProblems metOperation
Check operation of central locking Continue to Step 1 Central door locking not working either See table   P10 
1All OKProblems metOperation

Check::

  • service fuse
  • ignition-operated service fuse
  • supply to check instrument
  • earth for check instrument
  • connections between check and lock switches
  • connection between check and boot switch
  • earth for lock switches
( See   E4020  REV COUNTER INSTRUMENT ).
Continue to Step 2 Component defectiveReplace the component involved (if a fuse is involved, search for the cause of the problem)
Connections brokenRestore connections
2CHECK LOCK SWITCHESAll OKProblems metOperation
Check that the door lock switches are working Continue to Step 3 Fault in front door switches Check and if necessary replace the door lock motors Op.   7005N21 
Fault in rear door switches Check and if necessary replace the door lock motors Op.   7010N21 
Central door locking not working either See table   P10 
3CHECK ON CHECK INSTRUMENTAll OKProblems metOperation
Check the operation of the check instrument see DESCRIPTION AND OPERATION: 5560 INSTRUMENT PANEL Continue to Step 4 Instrument not working Replace check instrument Op.   5560C60 
4CHECKING CORRECT OPERATIONAll OKProblems metOperation
Check that the fault is no longer presentEnd of diagnosisFault persistsSearch for the fault starting from another symptom'
When the doors open (one or more), the warning on the Infocenter is not activated.
Results of the tests
0PRELIMINARY CHECKAll OKProblems metOperation
Check that the courtesy light works when the door switches are operated. Continue to Step 2 Fault in courtesy light Continue to Step 1
1CHECKING CONTINUITYAll OKProblems metOperation
Check the correct electrical connection of the switches on doors between earth point and dashboard / Infocenter junction. If the warning is issued when only one door is opened, check the individual electrical branch. See   E4024  INFOCENTER INSTRUMENT Continue to Step 2 Connections not correct.Renew the electrical connection.
Switch positioned incorrectly or faulty.Renew or replace the door switch.
2CHECK THE CORRECT INSTRUMENT OPERATIONAll OKProblems metOperation
Check the correct operation of the door open indicator on the Infocenter Continue to Step 3 Infocenter faultyReplace Infocenter.
3CHECKING CORRECT OPERATIONAll OKProblems metOperation
Check that the fault is no longer presentEnd of diagnosisFault persistsSearch for the fault starting from another symptom'