3233141 - P11 CENTRAL LOCKING / NOT WORKING WITH REMOTE CONTROL

When the central locking is operated using the remote control the doors do not open / close at all.
Results of the tests
0PRELIMINARY CHECKSAll OKProblems metOperation
Check the charge of the remote control battery incorporated in the keyCheck the correct operation of the central locking using the key Continue to Step 1 Remote control battery charge lowReplace battery
The central locking does not work with the key either See table   P10 
1CENTRAL LOCKING ELECTRICAL CIRCUIT CHECKAll OKProblems metOperation

Check, in order:

  • remote control receiver supply
  • connection between services control unit and remote control receiver
  • correct operation of remote control receiver
See   E3040  CENTRAL LOCKING
Continue to Step 2 Connections not correctRestore connections
Component defectiveReplace the component involved (if a fuse is involved, search for the cause of the problem)
Receiver not working Replace the receiver Op. 5080E30
2CORRECT OPERATION CHECKAll OKProblems metOperation
Check that the fault is no longer presentEnd of diagnosisFault persistsSearch for the fault starting from another symptom'
When the central locking is operated using the remote control the doors do not open / close at all.
Results of the tests
0PRELIMINARY CHECKSAll OKProblems metOperation
Check the charge of the remote control incorporated in the keyCheck that the central locking is working properly using the key Continue to Step 1 Remote control battery run downReplace battery
Central locking mechanical fault See table   P10  CENTRAL LOCKING
1REMOTE CONTROL RECEIVER CHECKAll OKProblems metOperation
Check the supply, earth and connections with the integrated electric windows central locking control unit Continue to Step 2 Connections damagedRestore the correct connections
Component defectiveReplace the alarm remote control receiver
2CENTRAL LOCKING ELECTRICAL CIRCUIT CHECKAll OKProblems metOperation

Check, in order:

  • central locking fuse, located in service control unit
  • connection between service control unit and junction unit
  • control unit supply ( See   E3040  CENTRAL LOCKING )
Continue to Step 3 Component defectiveReplace the component involved (if a fuse is involved, search for the cause of the problem)
Connection damagedRestore connections
3INTEGRATED ELECTRIC WINDOWS CENTRAL LOCKING ELECTRONIC CONTROL UNIT CHECKAll OKProblems metOperation
Check that the integrated electric windows central locking control unit is working properly Continue to Step 4 Control unit not working Replace integrated electric windows central locking control unit ( Op.   5505A18  )
4CORRECT OPERATION CHECKAll OKProblems metOperation
Check that the fault is no longer presentEnd of diagnosisFault persistsSearch for the fault starting from another symptom'