3239172 - 5040A Checking operation of air conditioner (temperature)
The test should be carried out at an ambient temperature of between 18° C and 30° C. |
Switch on the air conditioning (A/C button
pressed and LED on).Switch on the recirculation (button pressed
and LED on).Place the fan speed selector in position
"2".Place the temperature selector in the maximum cold
position.Place the distributor selector in the "frontal"
position.
Check that within 2 - 4 minutes the temperature reading
is 8 - 12° ?.