3237808 - 1060G10 flow meter - r r

Removing ( Refitting )  - 1048A50  air inlet pipe to turbo charger - r + r Make sure that the ignition is off (STOP position), then disconnect the negative battery terminal (refer to op.   5530B10  battery - r+r ).

NameConnector
-Battery  A1B 
1. Undo the bolts (1a) and move the relay holder backet (1b) away from the battery drip tray.2. Disconnect the flow meter electrical connection.

NameConnector
2Air flow meter  K41 
3. Undo the nuts (3a) and remove retaining plates (3b).4. Remove flow meter (4a) together with the sleeve from the flow meter to turbocharger air intake pipe (4b) and the sleeve from the filter to flow meter (4c).
Refitting ( Removing ) Fit the flow meter and sleeves, then secure using the nuts and plates.Connect the electrical connection to the flow meter.Place the relay holder bracket back in its housing and fix it using the bolts.Connect the negative (-) battery terminal. - 1048A50  air inlet pipe to turbo charger - r + r