3239155 - 1060GE Excess pressure sensor operation check

Make sure that the ignition is in the OFF position, then disconnect the negative battery terminal (refer to op.   5530B10  battery - r+r ). Disconnect the electrical connection from the supercharging pressure.

NameConnector
-Turbocharging sensor  K82 
Check that the nominal resistance of the supercharging pressure sensor corresponds to the recommended value.

MeasurementValue
-Nominal resistance (ohm)at +20°C2500 +/- 5%