3239158 - 1064AA Check on calibration of WASTE - GATE valve actuator calibration

Carry out op.   1072C44  exhaust manifold heat shield on bulkhead - r+r . Fit the tool fitted with the dial gauge to the actuator.

NameCountry
1Mount1.820.098.000
Connect an air line and pressure gauge to the actuator.Introduce air at a pressure of 0.86 - 0.91 bar and check that the travel on the dial gauge corresponds to the recommended value.

MeasurementValue
-Stroke (mm)1
air to (bar)0.86 - 0.91