3239478 - E6015 ADDITIONAL HEATER - Functional description

Functional description

Relays J36 and J37 control the engagement of the resistors O25 . The power supply to heating coils O25 arrives from the battery from the maxifuse HEAT line, located directly on the battery A1 connector D. The relay J36 controls the engagement of the first additional heater coil: the relay power supply is received from shunt fuse B38A; The climate control unit M70 sends the enabling signal for engaging the first resistance O25A from pin 12 of connector A: this signal energizes relay J36. The relay J37 controls the engagement of the other two additional heater coils. The relay power supply is received from shunt fuse B38B The control unit M70 sends a signal for enabling the engagement of the two resistances O25B and O25C from pin 40 of connector A: this signal energizes the relay J37.