3232864 - 1088E coolant temperature control devices
COMPONENT DESCRIPTION
FANS
Specifcations
FunctionThe two-speed electric cooling fans increase the heat dissipation capacity of the radiator and/or air conditioning condenser. They are controlled directly by the engine management control unit in accordance with a specific operating logic Characteristic of working principle 1060G pressure pump electric control .Control of the engine coolant temperature
At engine coolant temperatures above 105° C, the engine management control unit:
- reduces the quantity of fuel injected (reduces the engine power);
- operates the cooling fan through the fan interface;