125000575 - K09 DOORS OPEN CHECK WARNING LIGHT ON

The door open symbol in the Instrument Panel Node matrix remains on.
Results of the tests
0PRELIMINARY CHECKSAll OKProblems metOperation
Check that the two doors and the boot are properly shutContinue to Step 1Doors not properly closedMake sure they are properly closed. If the fault persists.Continue to Step 1
1CHECK WITH DIAGNOSTIC EQUIPMENTAll OKProblems metOperation
Using the Examiner check, in the Instrument Panel Node ambient, that there are no errors and the following parameters are present.Continue to Step 5Impossible to connect with the Instrument Panel control unitContinue to Step 2
There are errorsContinue in accordance with the instructions for the diagnostic equipment
2ELECTRIC POWER SUPPLY CHECKAll OKProblems metOperation
Check that the Instrument Panel Node electrical power supply is correctContinue to Step 3Positive and/or earth electrical power supply faultyReplace the component involved (if a fuse is involved, search for the cause of the problem)
3CHECK ELECTRICAL CONNECTIONSAll OKProblems metOperation
Check the electrical connections between the Body Computer and the Instrument Panel, in particular that each individual pin is correctly connected.Continue to Step 4Electrical connections not workingRestore damaged electrical connections.
4CHECK WITH DIAGNOSTIC EQUIPMENTAll OKProblems metOperation
Using the Examiner, check the possibility of connecting with the Instrument Panel NodeContinue to Step 5Impossible to connect with the Instrument PanelReplace the instrument panel Op.    Op. 5560B11 ANALOGUE CONTROL PANEL - R+R OR REPLACE
5CHECK WITH DIAGNOSTIC EQUIPMENTAll OKProblems metOperation
Using the Examiner, check, in the Body Computer Node ambient, that there are no errors and the door status parameter variesContinue to Step 1Impossible to connect with the Body Computer control unitContinue to Step 6
There are errorsContinue in accordance with the instructions for the diagnostic equipment
The parameter values do not changeContinue to Step 9
6ELECTRIC POWER SUPPLY CHECKAll OKProblems metOperation
Check that the Body Computer Node electrical power supply is correctContinue to Step 7Positive and/or earth electrical power supply faultyReplace the component involved (if a fuse is involved, search for the cause of the problem)
7CHECK ON CONNECTIONSAll OKProblems metOperation
Check the continuity of the wiring between the door lock geared motors and the Body Computer Node and between the boot opening switch and the Body Computer NodeContinue to Step 8Door electrical connections not workingRestore damaged electrical connections See    See E3040 CENTRAL LOCKING
Boot electrical connections not workingRestore damaged electrical connections See    See E3045 BOOT AND FUEL FLAP OPENING
8CHECK WITH DIAGNOSTIC EQUIPMENTAll OKProblems metOperation
Using the Examiner, check the possibility of connecting with the Body Computer NodeContinue to Step 5Impossible to connect with the Body Computer control unitReplace the Body Computer Node Op.    Op. 5505A32 BODY COMPUTER - R R
9CHECK ON CONNECTIONSAll OKProblems metOperation
Check the continuity of the wiring between the door lock geared motors and the Body Computer Node and between the boot opening switch and the Body Computer NodeContinue to Step 10Door electrical connections not workingRestore damaged electrical connections See    See E3040 CENTRAL LOCKING
Boot electrical connections not workingRestore damaged electrical connections. See    See E3045 BOOT AND FUEL FLAP OPENING
10CHECK ON CORRECT OPERATIONAll OKProblems metOperation
Check that the fault is no longer presentEnd of diagnosisThe fault persistsContinue to Step 1