125000702 - T10 PASSENGER COMPARTMENT WIND NOISE, LOWER AREA / (UNDERBODY)

With the vehicle moving, there is a noise coming from the lower part of the passenger compartment
Results of the tests
0PRELIMINARY CHECKSAll OKProblems metOperation
1.9 JTD 16V2.0 JTSCheck that the noise is actually coming from the underbody by carrying out the preliminary check for locating noisesContinue to Step 1The wind noise comes from the front dooorContinue according to the instructions inSee table    See table T01 WIND NOISE FROM THE FRONT DOORS
The wind noise is coming from the area of the bonnetContinue according to the instructions inSee table    See table T05 BONNET WIND NOISE
The noise is coming from the windscreen areaContinue according to the instructions inSee table    See table T06 WINDSCREEN WIND NOISE
The noise is coming from the rear areaContinue according to the instructions inSee table    See table T25 WIND NOISE FROM THE REAR AREA
3.2 V6Check that the noise is actually coming from the underbody by carrying out the preliminary check for locating noisesContinue to Step 2The wind noise comes from the front dooorContinue according to the instructions inSee table    See table T01 WIND NOISE FROM THE FRONT DOORS
The wind noise is coming from the area of the bonnetContinue according to the instructions inSee table    See table T05 BONNET WIND NOISE
The noise is coming from the windscreen areaContinue according to the instructions inSee table    See table T06 WINDSCREEN WIND NOISE
The noise is coming from the rear areaContinue according to the instructions inSee table    See table T25 WIND NOISE FROM THE REAR AREA
1UNDER ENGINE PARTITION CHECKAll OKProblems metOperation
1.9 JTD 16V2.0 JTSCheck the condition of the bulkhead under the engine and make sure that it is correctly fittedContinue to Step 2Bulkhead damaged or not fixed correctlyRenew or replace the bulkhead Op.    Op. 1072C44 EXHAUST MANIFOLD HEAT SHIELD ON BULKHEAD - R+R
2UNDERFLOOR CHECKAll OKProblems metOperation

Check the underfloor cover. In particular, ascertain:

  • The plugs are fitted;
  • The plugs are correctly fitted;
  • Seals present and correct
Continue to Step 3Faults in the underfloor coverRenew the plugs and seals for the underfloor cover
3CHECK ON CORRECT OPERATIONAll OKProblems metOperation
Check that the fault is no longer presentEnd of diagnosis.