125001021 - 1048A59 PIPE from flow meter to throttle casing hose - R.R.

Removing ( Refitting ) Proceed with removal    Op. 1016A40 IGNITION COIL COVER ON CYLINDER HEAD- R+R1. Disconnect the rapid connector for the vacuum intake pipe, pipe side from the flow meter to the throttle casing.2. Loosen the band for the engine oil vapour recovery pipe.3. Loosen the bands (3a) and remove the pipe from the flow meter to the throttle casing (3b).
Refitting ( Removing ) Place the pipe from the flow meter to the throttle casing back in its housing and secure it using the bands.Tighten the band for the engine oil vapour recovery pipe.Connect the rapid connector for the vacuum intake pipe, pipe side from the flow meter to the throttle casing.Proceed with refitting    Op. 1016A40 IGNITION COIL COVER ON CYLINDER HEAD- R+R.