125001287 - 2127E08 RUNNING THE HYDRAULIC SPEED SELECTION SYSTEM CONTROL UNIT SELF LEARNING PROCEDURE (Smart gearbox)
- Connect the Examiner diagnostic equipment.
- Select "Alfa Selespeed" on the Examiner.
- Select "Control unit Test" on the Examiner and select "Marelli Selespeed automatic transmission" as the system.
- Press "Active diagnosis" on the Examiner and select "End of line/service self-calibration".
- Follow the procedure indicated by the Examiner.