125001086 - 1072D22 AIR FLOW SWITCH CONTROL ACTUATOR R R

Removing ( Refitting ) Make sure that the ignition key is in the OFF position, then disconnect the negative battery terminal (-)
DescriptionConnector
-Battery See A1B BATTERY ( BATTERY NEGATIVE )
1. Disconnect the electrical connection from the switching control actuator enablement solenoid valve.
DescriptionConnector
1Variable geometry solenoid valve See L15 VARIABLE GEOMETRY CONTROL SOLENOID ( CONNECTORS )
2. Disconnect the vacuum intake pipe from the air flow switching device actuator and release it from the fastening on the latter.3. Disconnect the air flow switching device actuator linkage.4. Undo the bolts (4a) and remove the air flow switching device control actuator (4b).
Refitting ( Removing ) Place the air flow switching device control actuator back in its housing and secure it using the bolts.Connect the air flow switching device actuator linkage.Connect the vacuum intake pipe from the air flow switching device actuator and secure it to the band on the latter.Connect the electrical connection to the switching control actuator enablement solenoid valve.Connect the negative battery terminal (-).