125001273 - 2127A12 HAND LEVER OF MANUAL GEARBOX WITH HYDRAULIC SELECTION - R R (Smart gearbox)

Removing ( Refitting )

  • Make sure that the ignition key is in the OFF position, then disconnect the battery terminal (-).
DescriptionConnector
-Battery See A001 Battery

  • Undo the bolts fixing the electro-hydraulic selection manual gearbox control lever.
  • Remove the electro-hydraulic selection manual gearbox control lever (2a) after having disconnected the electrical connection (2b).
DescriptionConnector
2bGear controls See H37 GEAR CONTROLS
Refitting ( Removing )

  • Connect the electrical connection, then place the electro-hydraulic selection manual gearbox control lever back in its housing and secure it using the bolts.
  • Secure the electrical connection for the electro-hydraulic selection manual gearbox control lever using the fastening.
  •     Op. 7040L37 GEAR LEVER PLATE - R R
  •     Op. 7065C42 ASHTRAY (ONE) R+R
  • Place the trim in its housing on the tunnel cover.
  • Connect the negative battery terminal (-).