125001546 - 5040C80 AIR INTAKE AND RECIRCULATION FLAP - R R WITH AIR CONDITIONING HOUSING DISCONNECTED

Removing ( Refitting ) 1. Disconnect the electrical connection for the air recirculation and intake motor.
NameConnector
1Air intake actuator See N82 OUTSIDE / RECIRCULATION AIR INTAKE FLAP ACTUATOR
2. Undo the bolt.3. Rotate the air recirculation and intake assembly and remove it.
Refitting ( Removing ) Check that the air recirculation and intake flap is not damaged.Position and rotate the air recirculation and intake assembly and secure it using the bolt.Connect the electrical connection for the air recirculation and intake motor.