125001622 - 5520B10 STARTER MOTOR - R+R

Removing ( Refitting ) Position the vehicle on a lift.Make sure that the ignition key is in the OFF position, then disconnect the battery terminal (-).
DescriptionConnector
-Battery See A1B BATTERY ( BATTERY NEGATIVE )
Proceed with the removal    Op. 7055B54 UNDER-ENGINE GUARD - R R.Proceed with the removal    Op. 1076B18 RIGID SECTION OF EXHAUST PIPE BETWEEN CATALYTIC CONVERTER AND SILENCER - R + R.1. Undo the bolt (1a) and the nut (1b) and remove the exhaust pipe mounting (1c).
1. Disconnect the electrical connections from the starter motor.
DescriptionConnector
1Starter motor See A20 STARTER'' MOTOR
2. Undo the bolts (2a) and remove the starter motor (2b).
Refitting ( Removing ) 1. Place the starter motor (1a) in its housing and secure it tightening the bolts (1b) to the recommended torque.
FasteningComponentØ  Value(daNm)
1b----
2. Connect the electrical connections to the starter motor.
Place the exhaust pipe mounting back in its housing and secure it using the bolt and the nut.Proceed with the refitting    Op. 1076B18 RIGID SECTION OF EXHAUST PIPE BETWEEN CATALYTIC CONVERTER AND SILENCER - R + R.Proceed with the refitting    Op. 7055B54 UNDER-ENGINE GUARD - R R.Connect the negative battery terminal (-).Remove the vehicle from the lift.