125001015 - 1048A10 AIR CLEANER FILTERING ELEMENT - REPLACE

Removing ( Refitting ) Proceed with removal    Op. 5530B10 BATTERY - R+RProceed with removal1. Disconnect the electrical connection from the air flow meter.    Op. 5530B52 BATTERY DRIP TRAY/SUPPORT - R.R.2. Release the earth lead from the band on the air filter.
NameConnector
1Air flow meter See K41 AIR FLOW METER ( FRONT )
1. Remove the air filter (1a) complete with air flow meter (1b), after releasing it from the cold air intake pipe and from the pins fastening it to the lower radiator crossmember.
Refitting ( Removing ) Place the air filter, complete with flow meter, back in its housing, taking care to connect it to the cold air intake and then fit the pins on the air filter casing in the seats in the lower radiator crossmember.Secure the earth lead to the collar on the air cleaner.Connect the electrical connection to the air flow meter.Proceed with refitting    Op. 5530B52 BATTERY DRIP TRAY/SUPPORT - R.R..Proceed with refitting    Op. 5530B10 BATTERY - R+R.