125001526 - 5040A44 AIR CONDITIONER DEHYDRATING FILTER/ACCUMULATOR - R+R

Removing ( Refitting ) Observe the following precaution.
Follow the safety instructions (    Op. 5040 AIR CONDITIONING CASING AND COMPONENTS).
Drain the refrigerant (    Op. 0010T84 COOLANT FOR AIR CONDITIONING SYSTEM DEHYDRATE AND RECHARGE).    Op. 7055B54 UNDER-ENGINE GUARD - R R    Op. 7055B64 LH OR RH REFLECTOR(ONE) ON REAR BUMPERS - R R    Op. 7055B42 LH OR RH REFLECTOR(ONE) ON REAR BUMPERS - R R    Op. 7210E10 R.R. FRONT BUMPER1. Undo the bolts shown fastening the condenser.2. Undo the plug for the drier filter container.3. Release the retaining ring.4. Move the condenser (4a) slightly forwards and extract the drier filter cartridge (4b), tightening a threaded bolt for the tool indicated below or an M12x1.75 screw in the opening (4c).

NameCountry
4Extractor1.842.134.000
Seal the housing for the drier filter cartridge using a suitable plug to prevent dampness and impurities from entering the system.
Refitting ( Removing ) Check that the drier filter cartridge is not damaged.
Replace the O-rings for the connectors. Lubricate the thread of the connectors using anti-freeze.
Move the condenser slightly forwards and fit the drier filter cartridge.Fit the retaining ring.Tighten the drier filter container plug.Tighten the bolts fixing the condenser.    Op. 7210E10 R.R. FRONT BUMPER    Op. 7055B42 LH OR RH REFLECTOR(ONE) ON REAR BUMPERS - R R    Op. 7055B64 LH OR RH REFLECTOR(ONE) ON REAR BUMPERS - R R    Op. 7055B54 UNDER-ENGINE GUARD - R RRepressurize using refrigerant (    Op. 0010T84 COOLANT FOR AIR CONDITIONING SYSTEM DEHYDRATE AND RECHARGE).