125001556 - 5040D88 CONTROL MOTOR OF ANY FLAP - R R WITH AIR CONDITIONER CASING REMOVED

Removing ( Refitting ) 1. Unscrew the motor retaining bolt.2. Disconnect the electrical connections for the motor (2a, 2b, 2c, 2d).
NameConnector
2aLeft air mixture flap actuator See N78 LEFT AIR MIXTURE FLAP ACTUATOR ( CONNECTORS )
NameConnector
2bAir distribution actuator See N80 AIR DISTRIBUTION FLAP ACTUATOR (MOTOR)
NameConnector
2cRight air mixture flap actuator See N79 RIGHT AIR MIXTURE FLAP ACTUATOR
NameConnector
2dAir intake actuator See N82 OUTSIDE / RECIRCULATION AIR INTAKE FLAP ACTUATOR
3. Remove the motor (3a) releasing its connection (3b).
Refitting ( Removing ) Check that the motor is undamaged.Position the motor attaching its connection.Tighten the bolts fixing the motor.Connect the motor electrical connection.