125001638 - 5530B10 BATTERY - R+R

Removing ( Refitting ) 1. Loosen the band (1a) and disconnect the oil vapour recirculation pipe (1b) from the corrugated hose.2. Loosen the bands (2a) and remove the corrugated hose (2b), complete with resonator (2c).
1. Ensure that the ignition key is in OFF position, then disconnect the battery negative terminal (-).
NameConnector
1Battery See A1B BATTERY ( BATTERY NEGATIVE )
2. Open the maxi fuse box cover.3. Undo the bolts securing the ''maxi-fuse'' box to the battery.4. Loosen the bolt fixing the battery terminal (+).5. Release the maxi fuse box from the battery and move it to the side.
1. Undo the nut (1a) for the battery fixing belt (1b).2. Remove the battery.
Refitting ( Removing ) Place the battery back in its housing.Secure the battery with its belt and tighten the nut.Place the maxi fuse box back in its housing on the battery.Tighten the bolt securing the battery''s (+) terminal.Tighten the bolts securing the maxifuse box to the battery.Close the maxi fuse box cover.Connect the negative (-) battery terminalPlace the corrugated hose, complete with resonator, back in its housing and tighten the bands.Connect the oil vapour recirculation pipe to the corrugated hose and tighten the band.