125001835 - 7025C40 FUEL FILLER FLAP CONTROL MOTOR - R+R AND CHECK LOCK SUPPLY LINE

Removing ( Refitting ) Open the fuel filler access flap.1. Undo the retaining bolts.2. Extract the flap opening control actuator complete with mounting bracket/fuel flap striker.
1. Disconnect the electrical connector for the fuel flap opening control.
NameConnector
1Fuel flap geared motor See N58 FUEL FLAP LOCK GEARMOTOR
2. Undo the fixing bolts (2a) and remove the fuel flap opening control actuator (2b).
Refitting ( Removing ) Check the condition of the actuator.Position the actuator on the bracket/striker and secure it using the bolts.Connect the fuel flap opening control electrical connector.
NameConnector
-Fuel flap geared motor See N58 FUEL FLAP LOCK GEARMOTOR
Position the striker and actuator and secure it using the bolts.
It is advisable to secure a sensor cable to the fuel flap opening safety cord to facilitate positioning.