125002598 - 1056B10 AIR FLOW METER - R + R

Removing ( Refitting ) Ensure that the ignition key is in the OFF position, then disconnect the negative battery terminal (-).
NameConnector
-Battery    See A1B BATTERY ( BATTERY NEGATIVE )
Proceed with removal    Op. 1048A28 VACUUM AIR CIRCUIT RESONATOR PIPE - R+R1. Disconnect the electrical connection from the air flow meter.2. Undo the nuts (2s) and remove the brackets (2b) securing the air flow meter to the aiar filter cover.
NameConnector
1Air flow meter    See K41 AIR FLOW METER ( FRONT )
3. Remove the air flow meter (3a), complete with hose (3b).
Refitting ( Removing ) Refit the air flow meter in its seating complete with hose, then secure it using the brackets and nuts.Connect the electrical connection to the air flow meter.Proceed with refitting    Op. 1048A28 VACUUM AIR CIRCUIT RESONATOR PIPE - R+R.Connect the negative (-) battery terminal