125000451 - A05 ALARM LED NOT WORKING

When the alarm is operated, the LED does not come on
Results of the tests
1CHECK WITH DIAGNOSTIC EQUIPMENTAll OKProblems metOperation
Connect the diagnostic equipment (Examiner Plus or Smart) and check that there are no faults in the systemEnd of diagnosisFaults presentContinue to Step 2
2ACTIVE DIAGNOSIS WITH DIAGNOSTIC EQUIPMENTAll OKProblems metOperation
Using the diagnostic equipment, carry out the active diagnosis of the LEDContinue to Step 4LED does not come onContinue to Step 3
3WIRING CHECKAll OKProblems metOperation
Check the continuity and insulation of the wiring between the Body Computer and the panelCheck that the supply for the LED leaves the Body Computer and that the LED lights up See    See E7015 ALARMContinue to Step 4The supply does not leave the Body Computer for the LEDReplace the Body Computer Op.    Op. 5505A32 BODY COMPUTER - R R
The supply is sent correctly from the Body Computer but the LED does not come onReplace the LED in the panel Op.    Op. 5505A24 W/L AND SERVICE SWITCH MOUNT - R+R
4Continue as instructed by the testerAll OKProblems metOperation
Check that the fault is no longer presentEnd of diagnosis.